Fisher & Paykel OR24SDPWGX1 Guía de instalación Pagina 13

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 36
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 12
13
CONVERSION TO LP/PROPANE GAS
Every range is provided with a set of injectors for the various types of gas.
Select the injectors to be replaced according to the “INJECTORS TABLE”.
The nozzle diameters, expressed in hundredths of a millimetre, are marked on the
body of each injector.
SETTING THE PRESSURE REGULATOR (fig. 2.6)
The pressure regulator is accessible by removing the warmer drawer; the pressure
regulator is positioned on the rear right side of the range (fig. 2.9).
To remove the warming drawer:
1. Open the drawer completely (fig. 2.6)
2. Move down the lever of left guide (fig. 2.7) and up the lever of right guide (fig. 2.8).
3. Remove the drawer; the levers have to be keep moved (fig. 2.6).
Fig. 2.6
Fig. 2.8
Fig. 2.7
2
2
3
2
Vista de pagina 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 35 36

Comentarios a estos manuales

Sin comentarios